Skip to Product Info
    • Schneider Electric TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 240VAC 50/60Hz coil
    • Schneider Electric TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 240VAC 50/60Hz coil
    • Schneider Electric TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 240VAC 50/60Hz coil
    • Schneider Electric TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 240VAC 50/60Hz coil
    • Schneider Electric TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 240VAC 50/60Hz coil

    Schneider Electric TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 240VAC 50/60Hz coil

    Barcode: 3389110349115 | MPN: LC1D09U7 | SKU: SCDLC1D09U7
    Regular Price $63.95
    Payment & Security

    Your payment is secure. We don’t store or see your card details.

    • American Express
    • Apple Pay
    • Google Pay
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa
    Pairs well with

    Specifications

     

    Design

     

    Range of product

    TeSys Deca

    Product or component type

    contactor

    Warranty

    18 months

     

    Physical

     

    [ue] rated operational voltage

    • power circuit: <= 690 V AC 25...400 Hz
    • power circuit: <= 300 V DC

    [ie] rated operational current

    • 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    • 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    • 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

    Mechanical durability

    15 Mcycles

    Electrical durability

    • 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
    • 2 Mcycles 9 A AC-3 at Ue <= 440 V
    • 2 Mcycles 9 A AC-3e at Ue <= 440 V

    Connections - terminals

    • power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
    • power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
    • power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
    • power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
    • power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
    • power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
    • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
    • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
    • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
    • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end

    Insulation resistance

    > 10 MOhm for signalling circuit

    Mounting support

    • rail
    • plate

    Connections - terminals

    screw clamp terminals

    Standards

    • CSA C22.2 No 14
    • EN 60947-4-1
    • EN 60947-5-1
    • IEC 60947-4-1
    • IEC 60947-5-1
    • UL 60947-4-1
    • IEC 60335-1:Clause 30.2
    • IEC 60335-2-40:Annex JJ
    • UL 60335-2-40:Annex JJ
    • CSA C22.2 No 60947-4-1

    Product certifications

    • UL
    • CCC
    • CSA
    • Marine
    • UKCA
    • EAC
    • CB Scheme

    Ip degree of protection

    IP20 front face conforming to IEC 60529

    Climatic withstand

    • conforming to IACS E10 exposure to damp heat
    • conforming to IEC 60947-1 Annex Q category D exposure to damp heat

    Height

    77 mm

    Width

    45 mm

    Depth

    86 mm

    Net weight

    0.32 kg

    Reach free of svhc

    Yes

    Toxic heavy metal free

    Yes

    Mercury free

    Yes

    Rohs exemption information

    Yes

    Environmental disclosure

    ENVPEP1501004

    Eu rohs directive

    Compliant

    Reach regulation

    Free of Substances of Very High Concern above the threshold

    China rohs regulation

     Pro-active China RoHS declaration (out of China RoHS legal scope)

    California proposition 65

    WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

     

    Others

     

    Life cycle assessment data

    Yes

    Substance regulation data deliverable

    Yes

    Package 1 bare product quantity

    1

    Package 2 bare product quantity

    20

    Legacy weee scope

    In

    Average percentage of recycled plastic content

    0 %

     

    At least in Europe

    Weee label

    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

    Device short name

    LC1D

    Contactor application

    • motor control
    • resistive load

    Utilisation category

    • AC-3
    • AC-4
    • AC-1
    • AC-3e

    Poles description

    3P

    [uc] control circuit voltage

    240 V AC 50/60 Hz

    Motor power kw

    • 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
    • 4 kW at 380...400 V AC 50/60 Hz (AC-3)
    • 4 kW at 415...440 V AC 50/60 Hz (AC-3)
    • 5.5 kW at 500 V AC 50/60 Hz (AC-3)
    • 5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
    • 2.2 kW at 400 V AC 50/60 Hz (AC-4)
    • 2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
    • 4 kW at 380...400 V AC 50/60 Hz (AC-3e)
    • 4 kW at 415...440 V AC 50/60 Hz (AC-3e)
    • 5.5 kW at 500 V AC 50/60 Hz (AC-3e)
    • 5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)

    Motor power hp

    • 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    • 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
    • 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
    • 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
    • 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
    • 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors

    Compatibility code

    LC1D

    Pole contact composition

    3 NO

    Protective cover

    with

    [ith] conventional free air thermal current

    • 25 A (at 60 °C) for power circuit
    • 10 A (at 60 °C) for signalling circuit

    Irms rated making capacity

    • 250 A at 440 V for power circuit conforming to IEC 60947
    • 140 A AC for signalling circuit conforming to IEC 60947-5-1
    • 250 A DC for signalling circuit conforming to IEC 60947-5-1

    Rated breaking capacity

    250 A at 440 V for power circuit conforming to IEC 60947

    [icw] rated short-time withstand current

    • 105 A 40 °C - 10 s for power circuit
    • 210 A 40 °C - 1 s for power circuit
    • 30 A 40 °C - 10 min for power circuit
    • 61 A 40 °C - 1 min for power circuit
    • 100 A - 1 s for signalling circuit
    • 120 A - 500 ms for signalling circuit
    • 140 A - 100 ms for signalling circuit

    Associated fuse rating

    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
    • 25 A gG at <= 690 V coordination type 1 for power circuit
    • 20 A gG at <= 690 V coordination type 2 for power circuit

    Average impedance

    2.5 mOhm - Ith 25 A 50 Hz for power circuit

    Power dissipation per pole

    • 1.56 W AC-1
    • 0.2 W AC-3
    • 0.2 W AC-3e

    [ui] rated insulation voltage

    • power circuit: 690 V conforming to IEC 60947-4-1
    • power circuit: 600 V CSA certified
    • power circuit: 600 V UL certified
    • signalling circuit: 690 V conforming to IEC 60947-1
    • signalling circuit: 600 V CSA certified
    • signalling circuit: 600 V UL certified

    Overvoltage category

    III

    Pollution degree

    3

    [uimp] rated impulse withstand voltage

    6 kV conforming to IEC 60947

    Safety reliability level

    • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

    Control circuit type

    AC at 50/60 Hz

    Coil technology

    without built-in suppressor module

    Control circuit voltage limits

    • 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
    • 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
    • 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
    • 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz

    Inrush power in va

    • 70 VA 60 Hz cos phi 0.75 (at 20 °C)
    • 70 VA 50 Hz cos phi 0.75 (at 20 °C)

    Hold-in power consumption in va

    • 7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
    • 7 VA 50 Hz cos phi 0.3 (at 20 °C)

    Heat dissipation

    2...3 W at 50/60 Hz

    Operating time

    • 12...22 ms closing
    • 4...19 ms opening

    Maximum operating rate

    3600 cyc/h at 60 °C

    Tightening torque

    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
    • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

    Auxiliary contact composition

    1 NO + 1 NC

    Auxiliary contacts type

    • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
    • type mirror contact 1 NC conforming to IEC 60947-4-1

    Signalling circuit frequency

    25...400 Hz

    Minimum switching voltage

    17 V for signalling circuit

    Minimum switching current

    5 mA for signalling circuit

    Non-overlap time

    • 1.5 ms on de-energisation between NC and NO contact
    • 1.5 ms on energisation between NC and NO contact

    Contact compatibility

    M2

    Maximum motor phase current

    9 A

    [uc] control circuit voltage

    240 V

    Protective treatment

    TH conforming to IEC 60068-2-30

    Permissible ambient air temperature around the device

    • -40...60 °C
    • 60...70 °C with derating

    Operating altitude

    0...3000 m

    Fire resistance

    850 °C conforming to IEC 60695-2-1

    Flame retardance

    V1 conforming to UL 94

    Mechanical robustness

    • vibrations contactor open (2 Gn, 5...300 Hz)
    • vibrations contactor closed (4 Gn, 5...300 Hz)
    • shocks contactor open (10 Gn for 11 ms)
    • shocks contactor closed (15 Gn for 11 ms)

    Unit type of package 1

    PCE

    Number of units in package 1

    1

    Package 1 height

    5.000 cm

    Package 1 width

    9.400 cm

    Package 1 length

    11.400 cm

    Package 1 weight

    357.000 g
    Service & Support

    Warranty

    This product is backed by a 12-month warranty, covering defects in materials and workmanship under normal use.

    Technical Assistance

    Our dedicated support team is available to assist with product setup, operation guidance, and troubleshooting. Contact us via email for prompt service.

    Recently viewed